Bathrooms are divided into zones around the bath and shower. Downlights in Zone 1, above the bath or shower tray up to 2.25 m, and Zone 2, 0.6 m beyond it, need at least IPX4. Fit steam-proof (IP65) over a bath or shower. Every bathroom circuit needs RCD protection, and a qualified electrician should do the work.
BS 7671, the IET Wiring Regulations, divides a room containing a bath or shower into zones based on how likely each area is to get wet. The zone decides what electrical equipment can go there and how well it must be sealed.
[diagram:zones]
| Zone | Where it is | Minimum for a light fitting | What we recommend |
|---|---|---|---|
| Zone 0 | Inside the bath or shower tray | Equipment made for this zone only, rated IPX7 and powered by safety extra-low voltage (SELV) of no more than 12 V AC | Not relevant to downlights, which never sit in Zone 0 |
| Zone 1 | Directly above the bath or shower tray, up to 2.25 m from the floor | Splash-proof (IPX4), or IPX5 where water jets may be used for cleaning | Steam-proof (IP65) |
| Zone 2 | 0.6 m horizontally beyond the edge of Zone 1, up to 2.25 m from the floor | IPX4, or IPX5 where water jets may be used for cleaning | IP44 or higher, and IP65 close to a shower |
| Outside the zones | The rest of the room | No IP requirement | IP44 helps where steam collects |
Zone 1 is taller where a fixed shower head or water outlet is mounted above 2.25 m. It then extends up to the height of that outlet. Walk-in showers and wet rooms without a tray are measured differently, so ask your electrician to confirm the zones in your room.
Bathroom ceilings are often around 2.4 m high, so on paper a downlight above the bath can sit just outside the zones. We suggest you do not rely on this. Steam and spray rise, a raised shower head extends Zone 1, and sloping or lowered ceilings can bring the fitting within 2.25 m. Treat the ceiling directly above a bath or shower as Zone 1.
An IP rating, short for ingress protection, shows how well a fitting is sealed against solid objects and water. It is defined in the international standard IEC 60529 and has two digits.
An X in place of a digit means that part was not rated. IPX4 tells you a fitting resists splashing water but says nothing about dust. In a bathroom, the second digit is the one that matters most.
| Rating | Solid objects (first digit) | Water (second digit) | Where it suits |
|---|---|---|---|
| IP20 | Objects over 12.5 mm, such as fingers | No protection | Dry rooms such as living rooms and bedrooms |
| IPX4 | Not rated | Splashing water from any direction | Meets the minimum for Zones 1 and 2 |
| IP44 | Objects over 1 mm, such as wires and small tools | Splashing water from any direction | Zone 2, the rest of the bathroom and kitchens |
| IP65 | Dust-tight | Water jets from any direction | Over a bath or shower, and anywhere with heavy steam |
| IP67 | Dust-tight | Temporary immersion in water | Rarely needed for ceiling lights |
IP65 fittings are tested against water jets, which gives a good margin over the steam and spray a bathroom ceiling sees. That margin is why many retailers, including us, recommend IP65 over a shower. Some product sheets give the rating for the front of the fitting only. That is the part facing the room, which is the part exposed to steam and spray.
For a downlight directly above a bath or shower, look for these features.
[products:ultra-slim-fire-rated-ip65-downlight,magnetic-bezel-fire-rated-ip65-downlight,large-hole-retrofit-downlight-100mm]
Our ultra-slim downlight needs only 35 mm above the ceiling and switches between four colour temperatures. Our magnetic-bezel downlight comes in six finishes, including brushed chrome to match taps. Our 100 mm large-hole retrofit covers old 70–92 mm halogen holes without an adapter plate. All three are IP65, fire-rated to 90 min and insulation-coverable. Browse all IP65 bathroom downlights.
Position lights so they do not sit directly above where your head rests in the bath. Light falling slightly in front of you is more comfortable. In a standard shower enclosure, one downlight roughly over the middle usually gives enough light.
[photo:bathroom]
In a small bathroom or en-suite, much of the ceiling can fall within Zones 1 and 2, or close to them. The simplest approach is to fit IP65 downlights throughout, so every fitting matches and you do not have to work out exactly where each zone ends.
A small room rarely needs many fittings. Two to four downlights light most en-suites, depending on the size and layout. Place one over the shower, one near the basin and one or two for the rest of the room. Our guide to how many downlights you need has spacing rules for every room.
A downlight directly above the mirror lights the top of your head and casts shadows under your eyes. For shaving and make-up, add a mirror light or an illuminated mirror, or place a downlight slightly in front of where you stand.
Sloping ceilings in loft en-suites need extra care. The ceiling can drop below 2.25 m over the bath or shower, which puts the fitting inside Zone 1 or 2. Ask your electrician to check the zones before you choose positions.
Steam rises and collects at the ceiling, which is where downlights sit. Over time, moisture can get inside fittings with a low IP rating and shorten their life. An IP65 fitting keeps moisture out of the part that faces the room.
Each downlight is also a hole in the ceiling. Where there is a loft above, warm, damp air can pass through gaps around a fitting and condense in the cold loft. A sealed IP65 fitting closes the hole more tightly than an open fitting.
Good ventilation is the best defence against steam. A bathroom should have an extractor fan or other extract ventilation, and a fan with an overrun timer keeps running after you leave to clear the air. An electrician can often wire a fan to run with the bathroom light. The fan also needs an IP rating suitable for its zone.
Bathrooms often sit under a loft, or under another room in a flat or a house of three or more storeys. The same rules apply as anywhere else in the home.
If loft insulation will lie over the fitting, choose one marked insulation-coverable (IC). If the fitting is not IC-rated, keep the insulation clear or fit an insulation guard over it so heat can escape. See what IC-rated means.
Where the ceiling separates floors in a flat, a house of three or more storeys or a loft conversion, it commonly needs to keep its fire resistance under Approved Document B. A fire-rated downlight restores the fire resistance lost when the hole is cut. Its 30, 60 or 90 min rating relates to the ceiling construction it was tested in. If you prefer a fitting that is not fire-rated, a fire hood above it can do the same job.
In flats, ceilings between homes may also need to meet sound insulation rules under Approved Document E, where acoustic-rated downlights help.
A fitting that is fire-rated, IP65 and insulation-coverable covers most bathroom ceilings, which keeps things simple. Read fire-rated downlights explained, and check with your electrician or building control if you are unsure what your ceiling needs.
A bathroom is one of the few rooms where you spend time looking straight up. In the bath, a standard downlight above you shines into your eyes. A low-glare fitting sets the LED deep inside the body, so you see a soft glow in place of a bright point. Read more in our low-glare downlight guide.
For colour temperature, warm white (3000 K) feels relaxing for evening baths, and cool white (4000 K) gives clearer light for shaving, make-up and cleaning. A switchable fitting lets you choose on the day of installation. Choose high colour rendering (CRI 90) so skin tones look natural in the mirror. Our colour temperature guide has more detail.
A dimmable bathroom downlight gives bright light in the morning and a soft glow in the evening. There are limits on where switches can go near a bath or shower, so bathroom light switches and dimmers are usually fitted outside the room or use a pull cord. Your electrician will know where they can go.
BS 7671 requires all circuits in a bathroom to have additional protection from a residual current device (RCD) rated at 30 mA. An RCD cuts the power very quickly if it detects current leaking to earth, such as through a person. Older installations do not always have RCD protection on lighting circuits, so your electrician should check before adding or replacing bathroom lights.
Bathroom electrical work should be done by a qualified electrician. Some of it, such as a new circuit or adding to a circuit around a bath or shower, is notifiable under Part P of the Building Regulations in England and Wales. A registered electrician can self-certify the work and give you a certificate. Scotland and Northern Ireland have their own building standards.
You can measure the holes and the depth above yourself, with the circuit switched off at the consumer unit. Our guide to measuring for downlights shows how, and our guide on what to ask your electrician helps you brief them. When you are ready, answer a few questions and we’ll show what fits.
Yes, in the ceiling above the shower, as long as it is rated for the zone. The space above a shower tray is Zone 1 up to 2.25 m from the floor, which needs at least IPX4, or IPX5 where water jets may be used for cleaning. We recommend IP65. A qualified electrician should fit it, and the circuit needs RCD protection. See our IP65 bathroom downlights.
At least IPX4 in Zones 1 and 2, or IPX5 where water jets may be used for cleaning. Outside the zones there is no IP requirement, although IP44 helps with steam. For the ceiling above a bath or shower we recommend IP65, which is dust-tight and protected against water jets.
IP44 meets the minimum for Zones 1 and 2 where water jets will not be used for cleaning, and it suits the rest of the room. Over a bath or shower, IP65 gives a bigger margin against steam and spray. Fitting IP65 throughout a small bathroom keeps every fitting matching and avoids working out exactly where each zone ends.
The first digit shows protection against solid objects and dust. The second digit shows protection against water. IP65 means dust-tight and protected against water jets. IP44 means protected against objects over 1 mm and against splashing water. An X means that part was not rated, as in IPX4. See IP ratings in our glossary.
Bathroom zones, set out in BS 7671, show how likely each area is to get wet. Zone 0 is inside the bath or shower tray. Zone 1 is directly above it, up to 2.25 m from the floor. Zone 2 extends 0.6 m horizontally beyond Zone 1. Everything else is outside the zones. The zone decides the minimum IP rating.
Only if the ceiling needs to resist fire, which depends on the building. It commonly applies where the bathroom is below another floor in a flat, in a house of three or more storeys or in a loft conversion. A fitting that is fire-rated and IP65 covers most situations. Check with your electrician or building control. See fire-rated downlights explained.
We recommend a qualified electrician. Bathroom circuits need 30 mA RCD protection, and some bathroom electrical work is notifiable under Part P of the Building Regulations in England and Wales. A registered electrician can self-certify the work. You can measure your existing holes yourself with the circuit switched off at the consumer unit. See what to ask your electrician.
Yes. IP65 protects the fitting from steam, but it does nothing to stop condensation on walls, mirrors and ceilings, or the mould that can follow. An extractor fan with an overrun timer clears steam after you leave. Your electrician can often connect it so it runs with the bathroom light.
The Downlight Co. · All downlights · Guides · Help · Basket