A fire-rated downlight helps a ceiling keep its fire resistance after you cut a hole in it, for 30, 60 or 90 min depending on the ceiling it was tested in. You usually need them where a ceiling separates floors, as in flats, loft conversions and houses of three or more storeys. Building control can confirm what yours needs.
In many homes, a plasterboard ceiling is part of the fire protection between floors. It is designed to hold back fire and smoke for a set time, so people have longer to get out and firefighters have longer to act. Every hole you cut for a downlight is a weak spot in that barrier. Fire and hot gases can pass through the hole into the void above, then reach the floor or the room above much sooner than the ceiling was designed to allow.
A fire-rated downlight is built to close that gap in a fire. Designs vary. Many use a steel body with intumescent material, which swells up when heated and seals the opening. A tested fitting has been shown to keep the ceiling's fire resistance for the stated time, as long as it is installed as the instructions say.
[diagram:section]
The space above the hole matters for fire, for insulation and for fitting depth, so it's worth knowing what is there before you buy. Our guide to measuring for downlights explains how to check the hole size and the depth above safely.
The rating tells you how long a fitting has been shown to maintain the fire resistance of the ceiling it was tested in. A fitting tested in a 60 min ceiling construction should keep that ceiling performing for 60 min. It can't raise the performance of a ceiling that was only built for 30 min.
Each rating is tied to a specific ceiling construction, such as the type and thickness of plasterboard and the joists above. Many fittings are tested in several constructions and marked for 30, 60 and 90 min, so one product covers most homes. A fitting tested for 90 min is fine in a ceiling that only needs 30 min, as long as the instructions list that type of ceiling. Follow the instructions exactly, including the hole size, because the rating only holds if the fitting is installed as it was tested.
| Rating | What it means | Typical examples |
|---|---|---|
| 30 min | Keeps a 30 min ceiling's fire resistance | Ceilings between floors in many houses, loft conversions, the ceiling of an integral garage |
| 60 min | Keeps a 60 min ceiling's fire resistance | Floors between flats in many blocks |
| 90 min | Keeps a 90 min ceiling's fire resistance | Floors in some taller blocks of flats |
These are examples only. The rating your ceiling needs depends on the building, so check with building control or your electrician if you're unsure.
The Building Regulations set fire resistance for certain ceilings and floors. In England and Wales the guidance is in Approved Document B (fire safety). Scotland and Northern Ireland have their own building standards. If your work cuts holes in a ceiling that must resist fire, the holes need to be protected. BS 7671 (IET Wiring Regulations) also expects electricians to keep the fire resistance of any part of the building their work passes through.
Fire-rated downlights, or fire hoods, are commonly needed in these places.
A ceiling with only an unconverted loft above, in a house of one or two storeys, usually has no fire-resistance requirement. Many people fit fire-rated downlights everywhere anyway, so they don't have to work out which ceiling needs what. Rules change with the building, so if you are unsure, ask your electrician or your local authority building control team before you start. You can browse our fire-rated downlights to see what is available for your hole size.
If you want a fitting that isn't fire-rated, such as some trimless or decorative designs, a fire hood can protect the hole instead. A hood is a cover that sits over the fitting in the ceiling void. Like a fire-rated fitting, it uses intumescent material to seal the gap in a fire.
Hoods have some practical limits.
For most people, a fire-rated fitting is simpler because the protection is built in. Hoods make most sense when you have loft access, or when you have chosen a fitting that isn't made in a fire-rated version.
Fire rating and insulation are separate properties. A fitting can be fire-rated and still be unsafe to bury in loft insulation.
Only fittings marked insulation-coverable (IC) can have loft insulation laid over them. Other LED downlights need space around them to lose heat. If insulation covers a fitting that isn't IC, the LED and its driver can overheat, which shortens their life and can be a fire risk.
If your fitting isn't IC, you have two options.
Pulling insulation back leaves a cold spot above each light, and several lights add up to a noticeable gap. IC fittings let you keep the insulation continuous, which is why they are the usual choice below a loft.
In flats, the floor between you and your neighbours also has to limit sound. In England and Wales, Approved Document E (sound) sets the standard for new and converted homes. Holes cut in the ceiling below a separating floor can let more airborne noise through, such as voices and TV sound.
Acoustic-rated downlights have been tested to show they don't reduce the sound insulation of the ceiling they are fitted in. Some fire-rated fittings are also acoustic-rated. Check the product details for both.
If you own a leasehold flat, your lease may also need permission from the freeholder or management company before you alter ceilings. Check before you cut.
You can't always tell by looking. The most reliable evidence is the paperwork or a marking on the fitting itself.
To read a label on an installed fitting, switch the lighting circuit off at the consumer unit first. Many downlights are held by spring clips and can be eased down a little to see the body. Don't disconnect anything. If there is no marking and no paperwork, assume the fitting is not fire-rated.
If you are replacing old fittings, our guide to replacing halogen downlights with LED covers the options. An electrician can check what is in your ceiling, and our guide to working with an electrician explains what to ask.
| Myth | What's true |
|---|---|
| All LED downlights are fire-rated. | Some are and some aren't. Only rely on a stated rating. |
| LEDs run cool, so fire rating doesn't matter. | Fire rating is about a fire in the room below getting through the hole. The heat of the lamp has nothing to do with it. |
| A 90 min fitting makes my ceiling a 90 min ceiling. | A fitting keeps the ceiling's existing fire resistance. It can't add to it. |
| Fire-rated fittings can always be covered with insulation. | Only fittings marked insulation-coverable (IC) can be covered. |
| A fire-rated fitting is protected however it's installed. | The rating only holds if you follow the instructions, including the hole size. |
| Only kitchens need fire-rated downlights. | It depends on the ceiling and what is above it, whatever the room. |
Start with the ceiling. Check the rating covers your ceiling construction, then check the cut-out size, the recess depth above, whether the fitting will sit under insulation, and whether the room needs extra sealing. For bathrooms, see our bathroom zones and IP ratings guide.
[products:ultra-slim-fire-rated-ip65-downlight,large-hole-retrofit-downlight-100mm,fire-rated-ip65-gu10-downlight-insulation-guard]
All three are fire-rated to 90 min, insulation-coverable and steam-proof (IP65). Our ultra-slim downlight suits 70 mm holes and voids as shallow as 35 mm. Our 100 mm large-hole retrofit covers old 70–92 mm holes. Our fire-rated GU10 downlight with insulation guard takes a replaceable GU10 bulb. If you're not sure which suits your ceiling, answer a few questions and we'll show what fits.
You need them, or fire hoods, wherever the ceiling has to resist fire. That commonly includes ceilings between flats, between floors in houses of three or more storeys, in loft conversions and under rooms above an integral garage. A ceiling with only an unconverted loft above often has no requirement. Because it depends on the building, check with your electrician or local building control.
No. Many LED downlights are fire-rated, but some are not, including some trimless and budget designs. Only rely on a rating stated on the packaging, instructions or product details. If an installed fitting has no marking and you can't find its paperwork, treat it as not fire-rated. Browse our fire-rated downlights if you want the protection built in.
The number is how long the fitting has been shown to keep a ceiling's fire resistance, in the ceiling construction it was tested in. A 30 min ceiling needs a fitting tested for at least 30 min in that construction. A higher rating won't improve the ceiling. Many fittings are tested for all three, so check the instructions list your type of ceiling.
Only if the fitting is also marked insulation-coverable (IC). Fire rating and insulation rating are separate. Covering a fitting that isn't IC can make the LED and driver overheat. If yours isn't IC, keep insulation clear by the distance in the instructions, or fit an insulation guard over it. See what IC rating means.
No. A fire-rated downlight has the protection built in, provided it's installed as the instructions say. Hoods are for fittings that aren't fire-rated. You might still fit an insulation guard over a fitting that isn't insulation-coverable, which is a separate issue from fire protection.
It depends on the ceiling and what is above it, just as in any other room. If there's a flat or a room above that needs fire separation, use fire-rated fittings or hoods. Bathrooms also need the right IP rating for each zone, and plenty of fire-rated downlights are also steam-proof (IP65). Our bathroom zones guide explains the IP side.
Where the Building Regulations require a ceiling to resist fire, any holes you cut must be protected so the ceiling keeps that resistance. Fire-rated downlights and fire hoods are the usual ways to do it. Whether your ceiling is one of those depends on the building. Building control, or an electrician registered with a competent person scheme, can tell you.
Look for paperwork or a marking on the fitting. With the lighting circuit switched off at the consumer unit, you can usually ease a spring-clip downlight down to read the label on its body. Don't disconnect anything. Open-backed halogen fittings are usually not fire-rated. If there's no marking, assume it isn't and plan to replace it or add a fire hood.