Replacing halogen downlights with LED

If your halogen downlights take GU10 bulbs, you can usually swap to LED GU10 bulbs as long as the fittings are in good condition. MR16 bulbs run at 12 V from a transformer, so a straight swap often flickers. Replacing the whole fitting lets you add fire rating and better sealing at the same time.

Key points

  • GU10 bulbs have two stubby pins and run on mains. MR16 bulbs have two thin pins and usually run at 12 V from a transformer.
  • Swapping GU10 halogen bulbs for LED GU10 bulbs is simple if the fittings are sound.
  • MR16 conversions need a compatible LED driver or rewiring, which is a job for an electrician.
  • Old 85–92 mm holes need a large-hole fitting or an adapter plate.
  • Halogen-era dimmers often need replacing with a trailing-edge dimmer rated for LED.
  • A 6 W LED uses about an eighth of the power of a 50 W halogen.

Work out whether you have GU10 or MR16

Halogen downlights in UK homes usually take one of two bulbs. The type decides what you can do next, so check before you buy anything.

Switch the lighting circuit off at the consumer unit and let the bulbs cool, as halogen bulbs get very hot. Many bulbs are held in by a spring clip or ring. Remove it, ease the bulb out, and look at the pins and the printing on the bulb.

GU10 MR16
Pins Two short, thick pins with rounded ends Two thin, straight pins
How it connects Push in and twist to lock Push straight in
Voltage Mains, 230 V Usually 12 V
Transformer None Yes, in the ceiling void, one per light or one per group
Printing on the bulb GU10, 230–240 V MR16 or GU5.3, 12 V
Switching to LED Swap for LED GU10 bulbs if the fitting is sound Needs a compatible LED driver or rewiring by an electrician

If you still can't tell, look for a transformer in the ceiling void, through the hole or from the loft. A transformer means a 12 V system. See GU10 and MR16 in our glossary for more detail.

Swapping bulbs or replacing the fitting

If you have GU10 fittings, you can swap the halogen bulbs for LED GU10 bulbs. It's the quickest change and needs no wiring. It makes sense if the fittings are in good condition, fire-rated where they need to be, and suit the room.

Look closely at the old fittings first. Years of halogen heat can make lampholders brittle, discolour the fitting and harden the insulation on the cables just above. If you see scorching, cracked lampholders or brittle wiring, stop using that light and ask an electrician to replace it.

Replacing the whole fitting takes more work, but it lets you fix other problems at the same time.

  • Add fire rating where the ceiling needs it.
  • Seal against steam in a bathroom, or choose a fitting that can be covered by loft insulation.
  • Reduce glare with a light source set deeper into the fitting.
  • Move to an integrated LED fitting, with no bulb to change and a rated life usually stated as L70 hours.

Our guide to integrated LED or GU10 compares the two. Replacing fittings is mains electrical work, so use a qualified electrician.

Why MR16 swaps often go wrong

MR16 halogen downlights usually run at extra-low voltage (SELV), typically 12 V, from a transformer above the ceiling. Many of those transformers are electronic, were designed to run halogen bulbs of 20 W to 50 W, and have a minimum load. An LED MR16 might draw 4 W to 6 W. That can be below the transformer's minimum, so the LED flickers, flashes or doesn't light at all.

There are three ways forward, and each is a job for an electrician.

  1. Replace each transformer with an LED driver that is compatible with the new bulbs.
  2. Remove the transformers and rewire each position for mains GU10 lampholders, then use LED GU10 bulbs.
  3. Remove the old fittings and transformers and fit new integrated LED downlights.

The third option usually gives the best result, as it deals with the bulbs, transformers, fire rating and any hole-size problems in one go.

Old 85–92 mm holes

Many halogen downlights were fitted in larger holes than today's LED fittings need. Holes of 85 mm to 92 mm are common in older ceilings, while many modern LED downlights need 70 mm to 75 mm. A smaller fitting in a larger hole won't grip the ceiling, and its rim won't cover the gap.

Measure before you choose. With the lighting circuit switched off at the consumer unit, ease one old fitting down on its springs and measure straight across the hole in millimetres. Measure two or three holes and use the largest. Check the depth above too. Our guide to measuring for downlights shows how.

You then have three options.

  • Large-hole retrofit. A fitting with a wide bezel covers the old hole: ours suit holes up to 92, 127 or 159 mm, and our wide-bezel GU10 downlight covers 70–85 mm. See our downlights for 85–92 mm holes.
  • Adapter plate. An adapter plate covers the old hole and gives a smaller opening for a standard 70–75 mm fitting. Check the plate is approved for use with that fitting, as it may affect the fire rating.
  • Patch and re-cut. Filling the hole and cutting a new one is possible, but it is messy and means redecorating the ceiling.

Fire rating of old fittings

Many older halogen downlights were not fire-rated. Open-backed fittings, or ones with slots and holes in the body, give no fire protection. If the ceiling needs to resist fire, such as a ceiling between flats or between floors in a house of three or more storeys, those holes are a weak point.

Replacing them with fire-rated downlights restores the ceiling's protection. If you keep a fitting that isn't fire-rated, a fire hood above it can do the same job. Our guide to fire-rated downlights explains where they're needed and what the ratings mean.

Check the dimmer

If your halogen downlights are on a dimmer, it is probably a leading-edge type made for halogen, with a minimum load set for much higher wattages. A room with 6 halogen downlights at 50 W draws 300 W. Swap to 6 W LEDs and the total drops to 36 W, which may be below that dimmer's minimum. The result is often flicker, buzzing or lights that won't dim smoothly.

Plan to replace the dimmer with a trailing-edge dimmer rated for LED, and check its LED load range against your new total. Make sure the new bulbs or fittings are dimmable. Our guide to dimming LED downlights has a worked example and a troubleshooting table.

What you save on running costs

LEDs give similar light for a fraction of the power. A good 5 W to 6 W LED will usually give as much light as a 50 W halogen, but compare lumens on the packaging to be sure. The worked example below shows where the savings come from.

Assumptions. One 50 W halogen downlight compared with one 6 W LED downlight. Each is on for 3 hours a day, every day of the year. Electricity costs 25p per kWh, which is an example tariff only. Use the unit rate on your own bill for a real figure. We have left out the small extra power used by 12 V transformers.

50 W halogen 6 W LED
Energy per day (3 hours) 0.15 kWh 0.018 kWh
Energy per year 54.75 kWh 6.57 kWh
Cost per year at 25p per kWh £13.69 £1.64
Cost per year for 6 downlights £82.13 £9.86

In words, 50 W for 3 hours is 150 watt-hours, or 0.15 kWh. Over 365 days that is 54.75 kWh, which costs about £13.69 at 25p per kWh. The LED uses 6 W for 3 hours, which is 0.018 kWh a day, 6.57 kWh a year and about £1.64. That saves about £12 a year for each downlight, or about £72 a year for a room of 6.

To try your own numbers, such as a different tariff, wattage or hours of use, use the calculator.

Heat and safety

Halogen bulbs run very hot. Much of the energy they use becomes heat, which builds up in the fitting and the ceiling void. Over time that can discolour the ceiling around the light and dry out cables and lampholders.

LED downlights run much cooler, but the LED and driver still need to lose heat.

  • Only fittings marked insulation-coverable (IC) can have loft insulation laid over them. Keep insulation clear of other fittings, or use a cover.
  • Don't put an LED bulb in an enclosed fitting unless the bulb says it is suitable.
  • When you swap bulbs, switch off at the consumer unit and let halogen bulbs cool first. They stay hot enough to burn for some time after switching off.
  • Leave anything involving wiring, transformers or dimmers to a qualified electrician. Our guide to working with an electrician explains what to expect.

Choosing replacement downlights

Our 100 mm large-hole retrofit is made for old 70–92 mm holes, and the 135 and 170 mm versions cover holes up to 127 and 159 mm. It is fire-rated, steam-proof (IP65) and insulation-coverable. Our wide-bezel GU10 downlight covers 70–85 mm holes and takes a replaceable GU10 bulb. Our indirect anti-glare downlight fills 97 mm holes with soft, low-glare light. To narrow it down by hole size and depth, answer a few questions and we'll show what fits.

Questions

Can I just replace halogen bulbs with LED?

If your fittings take GU10 bulbs, yes. Switch off at the consumer unit, let the old bulbs cool, and fit LED GU10 bulbs with a similar or higher lumen output. Check the fittings for scorching or brittle lampholders first. If you have 12 V MR16 bulbs, a straight swap often flickers or fails because the transformer isn't designed for such a small load.

How do I tell if I have GU10 or MR16 bulbs?

Look at the pins. GU10 bulbs have two short, thick pins with rounded ends and twist to lock. MR16 bulbs have two thin, straight pins and push straight in. The bulb is usually printed with its type and voltage, such as GU10 230 V or MR16 12 V. A transformer in the ceiling void also points to MR16.

Why do my LED MR16 bulbs flicker?

Usually because the old transformer was made for halogen bulbs of 20 W to 50 W, and a 5 W LED is below its minimum load. It can also be the dimmer. The fix is a compatible LED driver, rewiring to GU10, or new integrated LED fittings. All three are jobs for an electrician.

Will LED downlights fit my old halogen holes?

It depends on the hole size. Many halogen holes are 85–92 mm, while many LED downlights need 70–75 mm. Measure with the circuit switched off at the consumer unit. For larger holes, choose a large-hole retrofit light, or an adapter plate made for the light you choose. Check the depth above as well.

How much will I save by switching to LED downlights?

It depends on your tariff and how long the lights are on. As an example, a 50 W halogen used 3 hours a day costs about £13.69 a year at 25p per kWh. A 6 W LED costs about £1.64 on the same basis, a saving of about £12 per light each year. Use your own unit rate for a real figure.

Do I need to change my dimmer switch when I switch to LED?

Often, yes. Dimmers made for halogen are usually leading-edge and have a minimum load far higher than a room of LEDs draws. That causes flicker and buzzing. An electrician can fit a trailing-edge dimmer rated for LED and check the new load sits inside its range. See our dimmer guide for more.

Are old halogen downlights a fire risk?

They run very hot, and over the years that heat can dry out cables and lampholders. Many are also not fire-rated, so they weaken a ceiling that needs to resist fire. If you see scorching, discolouration or brittle wiring, stop using the light and have an electrician check it. Fire-rated LED fittings deal with both issues.

Can I replace halogen downlights myself?

You can swap GU10 bulbs yourself with the circuit switched off. Replacing fittings, transformers or dimmers is mains electrical work for a qualified electrician. Some work, such as a new circuit or new lights in the zones around a bath or shower, is also notifiable under Part P in England and Wales, which a registered electrician can handle for you.