To measure for downlights, switch the lighting circuit off at the consumer unit, take out one fitting and measure straight across the hole in millimetres. Then measure from the ceiling surface up to the first obstruction above. Choose a fitting whose cut-out range includes your hole width and whose recess depth fits the space.
You need two measurements for each downlight, the width of the hole and the depth of space above the ceiling. Together they tell you which fittings will physically fit. Everything else, such as ratings and colour, is covered in our downlight buying guide.
Gather a few things first.
Switch the lighting circuit off at the consumer unit before you take a fitting down. Turning off the wall switch is not enough, because some wiring at the ceiling can stay live. Flick the wall switch afterwards to check the lights no longer come on. If the lights have been on, give them a few minutes to cool, as older halogen lamps in particular get very hot.
You are only measuring. Do not disconnect any wires. If anything looks damaged, scorched or loose, stop and call an electrician.
Your existing fitting hides the hole, so you need to take one down to see it.
[photo:measure]
Measure the hole, not the rim of the old fitting. The rim, or bezel, is always wider than the hole and will give you the wrong size.
Compare your figure with the cut-out range on each product. A fitting listed as 70–75 mm fits a hole from 70 mm to 75 mm. If your hole sits right at the edge of a range, check the neighbouring size as well.
| Hole width | Usually from | Browse |
|---|---|---|
| 55–60 mm | Mini downlights | 55–60 mm downlights |
| 65–70 mm | Many older LED and GU10 fittings | 65–70 mm downlights |
| 70–75 mm | Many current fire-rated LED downlights | 70–75 mm downlights |
| 85–92 mm | Older halogen fittings | 85–92 mm downlights |
| 95 mm and over | Very large old holes | Downlights for 93–159 mm holes |
The recess depth is the space a fitting needs above the ceiling surface. Each product lists it. To check you have enough, follow these steps with the fitting still hanging down.
[diagram:section]
Leave some spare room above the fitting for the cable and connector. Many integrated fittings also have a separate driver, which goes into the ceiling through the same hole and sits beside the fitting. Check there is space around the hole as well as directly above it.
If depth is tight, look at slim fittings, some of which need 50 mm or less. If you have plenty, you have more choice, including deep low-glare fittings and GU10 fittings, which often need 60 mm or more. Never notch or cut a joist to make room, as that can weaken the floor or roof above.
While the fitting is down, look at what the ceiling is made of and what sits above it. Both affect which fitting you need.
| What you find | What it means |
|---|---|
| Plasterboard on timber joists | The most common ceiling in UK homes. Standard downlights suit it. |
| Lath and plaster | Found in many older homes. Thin strips of wood with plaster pressed between them. It can crack or crumble when cut, so get advice before any new holes are cut. |
| Concrete | Common in some flats. A downlight cannot be recessed into solid concrete, so it needs a suspended or dropped ceiling below. |
| Loft with insulation | Choose an insulation-coverable (IC) fitting, or keep the insulation clear with a guard. |
| Another room or floor above | Check whether the ceiling needs to keep a fire rating. In flats, check sound insulation too. |
| A bathroom above | Look out for water pipes and waste pipes in the space. |
| A flat roof | The space can be shallow and may include insulation and a vapour barrier. Cutting holes can damage the barrier, so get advice first. |
Ceilings between floors in flats, in houses of three or more storeys, in loft conversions and over integral garages commonly need to keep their fire resistance under Approved Document B. Your electrician or building control can confirm what applies to your home. Read fire-rated downlights explained and see what insulation-coverable means.
Ideally, measure every hole you plan to reuse. Holes in the same room are often cut at different times or with different tools, so they can vary by several millimetres. At the very least, measure two or three in each room, including any that look different.
A simple way to keep track is to sketch the ceiling, number each hole and write its width and depth beside it. When you choose, use the largest width and the smallest depth.
Older halogen fittings often left holes of 85–92 mm, larger than many current LED downlights. You have three options.
[products:large-hole-retrofit-downlight-100mm]
If you enter your hole size in the downlight finder, it suggests a plate where one is needed.
If your hole is smaller than the fitting you want, it needs widening. An electrician can do this with a hole saw of the right size, which gives a clean, round edge for the new bezel to cover. Before cutting, they should check for cables, pipes and joists close to the hole. The alternative is a smaller fitting. Mini downlights fit holes of 55–60 mm.
If you are adding downlights where there are none, start with the layout. Decide how many fittings you need and where they go before anything is cut. Our guide to how many downlights you need gives spacing rules and worked examples.
Your electrician will then usually do the following.
New lighting points involve work on the mains wiring, and some of it may be notifiable under Part P of the Building Regulations. Read what to ask your electrician before you book. If you are replacing old halogen fittings, our guide to replacing halogen downlights with LED covers the extra checks. When you have your measurements, answer a few questions and we’ll show what fits.
Measure the width of the hole in the ceiling, not the rim of your existing fitting. Take the fitting down with the lighting circuit switched off at the consumer unit and measure straight across the middle in millimetres. Choose a downlight whose cut-out range includes that figure, and check its recess depth fits the space above.
There is no single standard. Many current LED downlights need a hole of 70–75 mm, while mini fittings use 55–60 mm and older halogen fittings often used 85–92 mm. Sizes vary between manufacturers and installers, so always measure your own holes. You can browse 70–75 mm downlights or choose another size.
Yes, with an adapter plate. The plate sits between the ceiling and the fitting and covers the gap, so you avoid patching the ceiling. Check it suits the fitting you have chosen, including its fire rating if your ceiling needs one. You can also choose a fitting made for larger holes. See our adapter plates and accessories.
It depends on the fitting. Some slim integrated downlights need 50 mm or less, while deep low-glare and GU10 fittings may need 60–95 mm or more. Measure from the ceiling surface up to the first obstruction and leave some spare room for the cable, connector and any driver. Each product page lists the recess depth.
Switch the lighting circuit off at the consumer unit first. Remove any GU10 lamp, then pull the fitting gently straight down. Fold the spring clips up against the body as it comes through the hole, and let it hang on its cable. Do not disconnect any wires. If the fitting will not come out easily, ask an electrician.
Yes. An electrician can widen the hole with a hole saw of the right size, which leaves a clean, round edge for the new bezel to cover. Before cutting, they should check for cables, pipes and joists close to the hole. Widening a hole by hand tends to leave a ragged edge that a bezel may not hide.
Choose a slimmer fitting, as some integrated downlights need 50 mm or less. If a pipe or cable is in the way, an electrician may be able to move the cable or shift the light slightly. Never notch or cut joists to make room, as that can weaken the structure. Our integrated vs GU10 guide explains why integrated fittings are usually shallower.